I am developing a model for air injection through a well into the ground. The surface integral I used is giving me zero flux - sintegral(integrand, named_boundary, named_layer) option. Will someone suggest a better option? The pde fie is attached (version 4.2.16). Thanks. |
Robert G. Nelson (rgnelson)
Moderator Username: rgnelson
Post Number: 447 Registered: 06-2003
| Posted on Friday, September 02, 2005 - 04:38 pm: | |
When I run your file on 4.2.16, the only report giving a zero result is the "(integrand, boundary, layer, region)" form. In that statement, you have specified evaluation in layer "screen" and region "well_screen". But that region is VOID in that layer, so the result of the evaluation is necessarily zero. Change the region of evaluation to 'domain', and you will get a non-zero value. |
|